CustomMHS Buyer's Guide

Lockers: Steel, Welded & Wire

Three different products get called a locker: knock-down steel lockers, all-welded industrial lockers, and wire tenant enclosures. They fail in different ways, cost very different money, and are specified with different numbers. This guide covers all three.

Covers: Hallowell · Strong Hold · WireCrafters Questions: 866-333-0728
Section One

The three kinds of locker

Pick the family first. Everything else follows from it.

Most locker mistakes happen before any dimension is chosen, because the buyer priced the wrong family. The three families solve different problems and sit at very different price points.

Family one

Knock-down steel

The familiar school and workplace locker. Formed sheet steel, shipped flat, assembled on site. Bodies are typically 24 gauge with 16 gauge doors.

Buy it for employee changing, clean personal effects, schools, offices, light industrial.

Family two

All-welded industrial

12 gauge steel, welded, arrives assembled. Three-point locking with padlock hasp. Weighs hundreds of pounds and costs several times a knock-down locker.

Buy it for tools, abuse, theft-prone areas, plants where a pried door is a real risk.

Family three

Wire tenant enclosure

Welded wire mesh in a steel angle frame, typically 7 ft 6 in. tall and sized in feet, not inches. Walk-in scale.

Buy it for resident storage in condos and senior living, multi-tenant industrial, bulk storage cages.

The quick test

What goes inside, and who is trying to get in? A coat and a lunch bag in a staffed building is a knock-down locker. A tool set in a plant with contractor traffic is all-welded. Bicycles, boxes and seasonal storage for tenants is wire. Buying up from the first to the second roughly quadruples the cost per opening, so make that decision deliberately rather than by reflex.

What this guide does not cover

Enclosed storage cabinets, modular drawer cabinets and flammable liquid cabinets are a separate decision with their own specification logic. See the Cabinets & Modular Drawer Storage guide for those. To browse what is in stock, see lockers, steel and wire.

Section Two

Reading a Hallowell model number

Six characters describe the whole locker. Learn them and you can compare any two quotes.

Hallowell model numbers are not arbitrary. Each position encodes a dimension, and the number after the dash is the tier count. Once you can read it, a quote stops being a list of codes and becomes a specification you can check.

U  1 5 1 8 - 1
U
Premium steel locker family
1
Units wide: 1 = single, 3 = three-wide bank
5
Width code: 5 = 15 in.
1
Depth code: 1 = 21 in.
8
Height code: 8 = 72 in. locker on a 78 in. frame
-1
Tier count: one opening per column
Worked: U1518-1 is a single 15 in. wide, 21 in. deep, 72 in. high one-tier wardrobe locker. U3548-2 is a three-wide bank, 15 in. wide, 24 in. deep, two-tier, so six openings at 36 in. each.

The codes

Position codes on the Premium line and its variants
PositionMeaningValues
LettersFamilyU Premium · URB Ready Built · USV Safety View · UMS MedSafe · USS stainless · UCTL cell phone · BSL bulk storage
Digit 1Units wide1 = single · 3 = three-wide bank
Digit 2Width2 = 12 in. · 5 = 15 in. · 8 = 18 in.
Digit 3Depth2 = 12 in. · 5 = 15 in. · 8 = 18 in. · 1 = 21 in. · 4 = 24 in.
Digit 4Height6 = 60 in. locker, 66 in. frame · 8 = 72 in. locker, 78 in. frame
After the dashTiers1, 2, 3, 4, 5, 6 or 16
Trailing lettersVariantG Galvanite · HDV heavy-duty ventilated · A assembled · ASB assembled with slope top and closed base
Where the decoder stops working

Two Premium models break the width rule: the sixteen-person U1788-16 (72 in. wide) and the wall-mounted U1482-4WM (48 in. wide).

Four families do not use positional encoding at all. Bulk storage states its dimensions literally, so BSL363690 is 36 by 36 by 90 in. Emergency response (HERL), Max View (HLV) and the cell phone line (UCTL) each use their own scheme. Read the published dimensions on those rather than decoding them.

Why the height code matters twice

The height digit gives two numbers: the locker body and the overall frame. A -8 locker is 72 in. of locker on a 78 in. frame, because the standard 6 in. legs sit underneath. A -6 is 60 in. on a 66 in. frame. When you are checking a ceiling, a soffit, a duct run or a sprinkler head, the frame height is the number that matters, and it is the one buyers most often forget.

Section Three

Choosing the tier configuration

Tier count is a headcount decision, not a storage-volume decision.

Tier is how many openings stack in one column. It sets both how many people a run serves and what each of them can put inside. In a 72 in. locker the arithmetic is simple: one tier gives one 72 in. opening, two tiers give 36 in. each, three give 24 in., six give 12 in.

1 tier
Full wardrobe, 60 or 72 in. openingHanging space for a coat or uniform, with a hat shelf above. The only configuration that takes full-length garments. One person per column.
2 tier
30 or 36 in. openingsDoubles headcount per foot of wall. Takes a folded coat, a bag and boots, but not a hanging uniform. The usual compromise in tight rooms.
3 tier
24 in. openingsBags, boots, helmets and personal effects. Not for garments. Three people per column.
4 tier
18 in. openingsOffered on the Safety View box line. A middle point between wardrobe and box use.
5 & 6 tier
12 in. box lockersWallets, phones, keys, small personal effects. High headcount per square foot. Common for shift changes and visitor storage.
16 person
Sixteen compartments in one 72 in. wide unitMaximum headcount in minimum floor space, for facilities storing only small items.
Count people first, then check the garment

Work out how many openings the shift needs, divide by the wall length you have, and see what tier that forces. Then ask whether that opening actually holds what people bring. If the answer is a winter coat and the arithmetic says three-tier, you need more wall, not a smaller locker. A locker people cannot close is a locker that stays open.

Wardrobe and box lockers latch differently

This is a real durability difference that rarely appears on a quote. Wardrobe lockers (1, 2 and 3 tier) use a multi-point latch with a recessed handle and gravity-lift latching. Box lockers (4, 5, 6 and 16 tier) use a projecting single-point friction catch pull. The friction catch is simpler and cheaper, and it is also the part that wears in heavy-turnover installations. If a box locker bank will see hundreds of open-and-close cycles a day, plan on it as a wear item.

Section Four

Width, depth and frame height

Three dimensions, and only one of them is usually chosen well.

Width

Published widths are 12, 15 and 18 in. per opening. Twelve inches is the default and it is adequate for a coat and a bag. Fifteen inches is the upgrade that makes a locker comfortable rather than tolerable, and it is the right call anywhere people change clothes daily. Eighteen inches is for bulky gear, turnout equipment, helmets and cold-weather outerwear.

Lockers are sold as single units or as three-wide banks. A three-wide bank is one factory assembly sharing side panels, which is cheaper per opening and faster to install than three singles. Order banks wherever the run allows and use singles only to finish an odd end.

Depth

Published depths are 12, 15, 18, 21 and 24 in., though the deeper options are not offered on every line. Depth is where money gets wasted, because it is easy to assume deeper is better. It is not: depth is the least accessible dimension in a locker, and anything at the back of a 24 in. locker is out of sight.

Depth by line, from published listings
LineDepths offered
Premium12, 15, 18, 21, 24 in.
Heavy-Duty Ventilated12, 15, 18, 21 in.
Safety View, Galvanite, Ready Built12, 15, 18 in.
MedSafe and Type 304 stainless18 in. only

Twelve inches suits box lockers and personal effects. Fifteen inches is the general-purpose choice. Eighteen inches and deeper is for gear, boots and equipment that genuinely needs the floor area.

Frame height and the 6 in. legs

Standard Premium lockers ship on 6 in. legs, which is why a 72 in. locker occupies 78 in. and a 60 in. locker occupies 66 in. The legs raise the locker off the floor so the room can be cleaned underneath, which matters more than it sounds in food, healthcare and industrial settings.

Measure to the frame height, plus the top

If you add a sloped top, the overall height grows again by the top's rise. Published individual slope tops run from 4 in. on a 12 in. deep locker up to 8 in. on a 24 in. deep locker, because the pitch is constant and the deeper the locker, the taller the rise. A 78 in. frame with a 24 in. deep sloped top is 86 in. to the peak. Check that against the ceiling before ordering.

Section Five

Door style and ventilation

The door decides airflow, sightlines and how hard the locker is to defeat.

Door style is not cosmetic. It governs whether wet clothing dries, whether staff can see contents without opening every door, and how much abuse the locker takes.

Standard

Louvered steel

Pressed louvers give modest airflow. The default on Premium wardrobe (16 gauge doors), Premium box (18 gauge), MedSafe and Galvanite. Right for general workplace and school use.

Visibility

Safety View polycarbonate

16 gauge steel doors carrying clear polycarbonate panels, with a full-length piano hinge. Contents visible without opening. Used where inspection matters: secure sites, schools with contraband policies, contractor areas.

Airflow

Heavy-Duty Ventilated

Diamond-perforated doors and sides for airflow through the whole body, with 14 gauge doors on a 16 gauge frame and body. The choice for wet, sweaty or contaminated clothing.

Maximum visibility

Max View all-welded

Expanded metal sides and diamond-perforated doors giving four-sided visibility, with a 14 gauge perforated door, full-height welded stiffener and 13 gauge hinges. Welded-in shelves rather than a hanging bar.

Ventilation is a maintenance decision

Damp clothing in a louvered locker is the origin of most locker room odor complaints, and odor is what gets a locker bank replaced early. If people put away wet or sweaty clothing, specify the ventilated line at order time. Retrofitting airflow is not possible; you replace the locker.

Across the Hallowell wardrobe and box lines carried here, doors are published as louvered, polycarbonate or perforated rather than solid. If you need a fully solid door for privacy or containment, that points toward the all-welded lines in Section Ten.

Section Six

Knock-down, ready built or all-welded

The single biggest driver of installed cost, and it is decided three different ways.

Buyers routinely compare a knock-down price against an assembled price and conclude the assembled locker is expensive. The comparison is wrong, because it leaves out the labor. What matters is the installed cost, and how the choice is expressed differs by line.

Knock-down, standard
Ships flat, assembled on site. The default on the Premium U line. Lowest freight and lowest purchase price, highest labor. The model number does not change.
Fully assembled option
Selected on the product page as an option against the same model number. Ships built. Higher freight, no site labor.
Ready Built URB
A separate factory-assembled family with an A suffix, for example URB1228-1A. Arrives built, and published as including one combination padlock and strike plate per door.
Ready Built II URB…ASB
Factory-assembled with a slope top and closed base already fitted, for example URB1228-1ASB. Also published as including one combination padlock and strike plate per door.
All-welded
Strong Hold, Max View and the emergency response line. Welded at the factory, no assembly option, arrives complete and heavy.
Accessories follow the assembly choice

Several Hallowell accessories are published as fitting knock-down lockers only, including coat rods and the flat top and corner fillers. If you order Ready Built lockers and then try to add those parts, they will not fit. Decide assembly method before you build the accessory list, not after.

How to actually choose

Knock-down makes sense for a large run in an accessible room where you have labor available and freight cost matters. Ready Built makes sense for small quantities, awkward access, occupied buildings, and any job where assembly labor is billed at contractor rates. Ready Built II makes sense when you were going to add a slope top and closed base anyway, since buying them fitted removes both the parts and the fitting.

Section Seven

Locks and access control

Including the one compatibility trap that catches people every time.

Lockers ship without locks unless the line states otherwise, and the lock is a separate decision from the locker. There are three published Zephyr options plus padlock-provision hardware.

Published Hallowell lock options
PartTypeNotes
1970Built-in combination lockManually operated deadbolt. No key or padlock for the user to lose.
1770Built-in key lockManually operated deadbolt. For assigned lockers where management holds keys.
1925Combination padlockKey-controlled. Hangs on a hasp rather than fitting into the door.
Check this before you order built-in locks

The built-in locks (1970 and 1770) are published as not recommended for single-point-latch wardrobe doors. Confirm the latch type on the exact locker you are buying before adding built-in locks to the order. Where they are not suitable, the padlock route (1925 on a hasp) is the published alternative. Getting this wrong means a box of locks that will not fit the lockers.

Assigned or unassigned

This decision drives the lock type more than security level does.

Electronic and small-item lockers

The cell phone and tablet line encodes locking in the model number rather than as an accessory: -PL is a padlock provision for a user-supplied lock, -K-PL is an individual key lock, and -E-PL is a DigiTech electronic keypad. The price gap between them is substantial, since the electronic version runs several times the padlock version, so decide what the application actually needs.

At the high-security end, the emergency response line uses a three-point cremone locking system, and the all-welded industrial lockers in Section Ten use three-point locking with a padlock-ready hasp as standard.

Decide keying before the purchase order

Keyed alike, keyed differently, or master keyed costs nothing to specify at order time and is a genuine nuisance afterward. Say which on the PO. Note also that master-keyed Zephyr padlocks are published as available, which is usually what a facility with turnover actually wants.

Section Eight

Bases, tops and fillers

The parts that turn a row of lockers into a finished installation.

A bare locker run has three problems: an open gap under the legs that collects debris, a flat top that collects debris, and untidy gaps where the run meets a wall or turns a corner. Each has a published part.

Closed bases

Standard lockers sit on 6 in. legs, leaving an open recess. Closed bases fill it with 16 gauge cold-rolled steel, 6 in. high. Order a front base sized to the locker width and a side base sized to the locker depth for the ends of a run.

Base part numbers
PartFits
KCFB12 · KCFB15 · KCFB18Front base, 12 / 15 / 18 in. wide, 6 in. high
KCSB12 · KCSB15 · KCSB18 · KCSB21 · KCSB24Side base, 12 to 24 in. deep, 6 in. high
KCFB12SS · KCFB18SS · KCSB18SSStainless equivalents

Sloping tops

A flat locker top becomes a shelf for anything anyone wants to put down, and in food, healthcare and cleanroom settings it becomes a dust ledge. Sloping tops are published at an 18 degree pitch in three forms.

Both individual and continuous versions need end closures to cap the exposed triangle at the end of a run: KISE for individual tops, CSE for continuous.

Fillers and slip joints

Fillers close the gaps between the locker run and the building. Front fillers (KFSF) come in 6 and 12 in. widths at both 66 and 78 in. heights, matching the two frame heights. Slip joints (KG66, KG78) join runs. Flat top fillers (KFTF) and corner fillers (FTC) close the tops, and both are published for knock-down lockers only.

Order fillers with the lockers

Fillers are the parts everyone forgets, and they are what separates an installation that looks built-in from one that looks dropped in place. Measure the wall, subtract the total locker width, and order fillers for the remainder in the same purchase order. Chasing them afterward means a second freight charge on a few pounds of sheet steel.

Coat rods and benches

Single-tier lockers include a hat shelf, a double-prong ceiling hook and two single hooks as standard. Coat rods are extra, published in 12, 15, 18 and 24 in. lengths (KCR12 through KCR24) and designed for knock-down lockers. Benches are assembled from pedestals (steel, cast iron, aluminum, stainless or adjustable height, all 16-1/4 in. tall) plus a maple top sized from 36 to 144 in.

Section Nine

Matching material to environment

Where standard painted steel will not last, and what replaces it.

Standard lockers are painted cold-rolled steel. In a dry, heated, indoor room they last decades. In damp, washdown, coastal or chemically active environments they rust from the inside of the seams outward, and no amount of repainting fixes it. Four alternatives are published.

Material options and where each belongs
LineConstructionSpecify it for
Galvanite24 gauge galvannealed body, 16 gauge galvannealed doors, piano hinges, 6 in. legsDamp and corrosion-prone areas: pool decks, car washes, coastal sites, unheated buildings
MedSafe16 gauge louvered steel with an antimicrobial powder coat finishHealthcare, labs and clinical areas where surface hygiene is specified
Type 304 stainlessStainless throughout, 18 in. depth only, 1 / 2 / 6 tierWashdown, food processing, pharma and cleanroom. The most expensive option by a wide margin
Heavy-Duty Ventilated14 gauge doors, 16 gauge frame and body, perforated doors and sidesWet or contaminated clothing, where the problem is moisture rather than corrosion
Stainless is a last resort, not an upgrade

Type 304 stainless lockers run roughly five times the price of the equivalent painted Premium locker. Specify it where washdown chemicals or a regulated hygiene standard genuinely require it. Where the problem is only dampness, Galvanite solves it at a fraction of the cost.

Colors

Locker product pages publish Dark Gray, Tan, Marine Blue, Black and Light Gray. Accessory pages use a different set, Parchment, Hallowell Gray and Marine Blue, with additional colors on request. That mismatch matters: if you want bases, slope tops and fillers to match the lockers, confirm the accessory color against the locker color before ordering rather than assuming the names line up.

Section Ten

All-welded industrial lockers

When the door being pried open is the actual risk.

Strong Hold lockers are a different product from formed sheet lockers, and the specification reads differently. Published construction across the line is 12 gauge all-welded steel with 7 gauge welded 6 in. legs, three-point locking with a padlock-ready hasp, and 14 gauge adjustable shelving where shelves are fitted.

For comparison, a Premium knock-down locker has a 24 gauge body. Lower gauge numbers mean thicker steel, so 12 gauge is dramatically heavier material, and the whole assembly is welded rather than bolted. A 54 in. wide six-door vented unit is published at 684 lb; a 12-compartment unit at 1,018 lb; a 36-compartment bank at 1,568 lb.

The configurations

Strong Hold locker families, from published listings
FamilyExample modelConfiguration
Single tier slim line16-18-1TSL14 in. wide, 18 in. deep, 72 in. high, one door and a shelf. Widths run up to 122 in. and ten doors.
Two tier slim line36-18-2TSL36 in. wide with six doors, openings 10 in. wide by 32 in. high
Standard two tier46-24-2TPL50 in. wide, 24 in. deep, 78 in. high, four doors
With drawers46-24-2TPL-8DBSix shelves plus eight drawers. Drawers published at 400 lb each
Mini tier55-18-3TMT62 in. wide, twelve 18 in. cube compartments
Vented door4.76-34-V-2TPL54 in. wide, 34 in. deep, six ventilated doors
Personal effects7.56-16D-WR-180Sixteen louvered compartments plus a wardrobe rod, ships in three pieces
Cell phone54-16D-120CL58 in. wide, 12 in. compartments, individually keyed with a master key
Read the shelf capacity, not just the locker

Published shelf ratings differ by family: 775 lb per half-width shelf on the standard two-tier and drawer models and 500 lb on the slim line, with the single-tier shelf models published individually (one lists 650 lb per shelf, another a 1,900 lb total). If the locker is storing tooling rather than clothing, that number is the one that decides whether it does the job.

Overall height and slope tops

Strong Hold lockers publish both a locker height and an overall height, and the gap is the 6 in. welded legs: a 72 in. locker is 78 in. overall. Adding a slope top increases it further. One published two-tier slope top model is 72 in. of locker at 85 in. overall. As with the knock-down lockers, the overall height is the number to check against the ceiling.

What it costs

All-welded lockers run several times the price of knock-down steel per opening, and they weigh enough to change how they are delivered and placed. That premium buys steel thickness, welded joints and three-point locking. Specify it where tools are stored, where theft is a live problem, or where the room sees genuine abuse. In a clean office or school, it is money spent on a risk that is not there.

Section Eleven

Wire tenant and bulk storage lockers

Sized in feet, not inches, and specified as a run rather than as units.

Wire lockers solve a different problem: giving a resident or tenant a lockable space large enough to walk into. WireCrafters tenant lockers are published at 7 ft 6 in. high in widths of 3, 4 and 5 ft and depths of 3, 4 and 5 ft. The product listings publish the mesh specification as 10 gauge wire in a 2 in. by 2 in. welded wire mesh, welded into a 1-1/4 in. by 1-1/4 in. 13 gauge roll-formed angle.

Starters and add-ons

Wire lockers are quoted as a run, not as individual units, and the suffix tells you which part you are buying.

-S Starter
The beginning section of a run. Includes its own framing on both sides.
-A Add-on
Extends an existing row by sharing framing with the unit before it. Cheaper than a starter.
-DS Double starter
Two-compartment starter, stacked as a double tier, with shared framing.
-DA Double add-on
Two-compartment double-tier extension unit.
One starter per run, add-ons for the rest

A ten-unit row is one starter and nine add-ons, not ten starters. Quoting it as ten starters overprices the job by a meaningful margin, because every add-on shares a frame with its neighbor. Confirm the split when you compare quotes.

The D in the double models means double tier, two compartments stacked vertically in the same footprint, not a wider door. That doubles the number of tenants served per square foot of floor, at the cost of each compartment being roughly half height.

Hallowell bulk storage lockers

The BSL line is the industrial equivalent: welded wire mesh and reinforced steel frames with a full-height padlock hasp and welded door frame, published at 90 in. high in 36 and 48 in. widths and 36, 48 and 60 in. depths. The suffixes follow the same starter and add-on logic. 1S is a single-tier starter, 1A a single-tier add-on, 2S and 2A the double-tier versions. Optional backs, tops and floor panels are available.

Military and tactical gear

The WireCrafters TA-50 gear locker is published at 24 in. deep by 42 in. wide by 78 in. high, with custom sizes available. Construction is 1-1/2 in. square 10 gauge welded wire, or 1-1/2 in. 13 gauge expanded metal, on a 1-1/4 in. angle and channel frame, with a 16 gauge formed top, a 14 gauge formed bottom and a 20 gauge back. It includes a 16 gauge shelf, a hot-dip galvanized 3/4 in. schedule 40 pipe coat rod and three coat hooks, and uses a three-point cane bolt lock with a padlockable handle. It is available fully assembled or knocked down.

Section Twelve

OSHA, ADA and layout

Two requirements that change what you order, and the clearances that make a room work.

OSHA change rooms

Where employees must wear protective clothing because of possible contamination with toxic materials, OSHA requires change rooms with separate storage for street clothes and for the protective clothing. The regulation reads:

29 CFR 1910.141(e)

"Whenever employees are required by a particular standard to wear protective clothing because of the possibility of contamination with toxic materials, change rooms equipped with storage facilities for street clothes and separate storage facilities for the protective clothing shall be provided."

In practice that means two separate lockers or two separate compartments per affected employee, not one locker with a divider. This is the requirement most often missed at specification stage, and it doubles the opening count for the affected headcount. Confirm which of your standards trigger it before you size the room.

ADA accessible lockers

The 2010 ADA Standards set both a quantity and a reach requirement.

ADA requirements affecting locker specification
RequirementStandardCitation
Quantity"Where lockers are provided, at least 5 percent, but no fewer than one of each type, shall comply with 811."225.2.1
High reach48 in. maximum above the floor, forward or side308.2.1 / 308.3.1
Low reach15 in. minimum above the floor, forward or side308.2.1 / 308.3.1

The reach range is what makes this a specification decision rather than a layout decision. A usable opening has to fall between 15 and 48 in. above the floor, which rules out the upper tier of most stacked configurations. In a two-tier bank on 6 in. legs, only the lower opening is within reach range. That means your accessible lockers are effectively lower-tier openings, and the 5 percent applies to each type of locker you install, not to the total.

Verify against your jurisdiction

State and local accessibility codes can be stricter than the federal standard, and some occupancies have their own requirements. Confirm the count and the mounting heights with your architect or authority having jurisdiction before ordering, particularly on new construction and permitted renovations.

Layout and clearance

Section Thirteen

Common and costly mistakes

Twelve things that go wrong on locker orders.

  1. Measuring to the locker height instead of the frame height. A 72 in. locker needs 78 in. of clear height on standard legs, and more again with a sloped top.
  2. Choosing tier count from wall length alone. Work out the headcount, then check the opening actually holds what people bring. A three-tier locker will not take a winter coat.
  3. Ordering built-in locks for single-point-latch doors. The built-in locks are published as not recommended for those doors. Confirm the latch before ordering locks.
  4. Comparing knock-down against assembled on purchase price. The comparison that matters is installed cost, including labor.
  5. Ordering knock-down-only accessories for Ready Built lockers. Coat rods and flat top fillers are published for knock-down lockers only.
  6. Forgetting fillers. Measure the wall, subtract the locker run, and order fillers for the remainder on the same PO.
  7. Buying louvered doors for wet clothing. Ventilation cannot be retrofitted. Specify the ventilated line at order time or plan on odor complaints.
  8. Buying depth you cannot reach. Depth is the least accessible dimension. Twenty-four inches is for gear, not for general use.
  9. Assuming accessory colors match locker colors. The two lists are published differently. Confirm before ordering bases, tops and fillers.
  10. Quoting a wire locker run as all starters. One starter, then add-ons. Every add-on shares framing with its neighbor.
  11. Missing the OSHA separate-storage requirement. Where protective clothing may be contaminated, street clothes and protective clothing need separate storage, which doubles the openings for that headcount.
  12. Treating ADA as a layout afterthought. The 15 to 48 in. reach range makes accessible lockers lower-tier openings, and the 5 percent applies to each type installed.
Section Fourteen

Frequently asked questions

The questions that come up most often on locker quotes.

How do I read a Hallowell locker model number?

Reading left to right: the letters give the family, the first digit is how many units wide (1 or 3), the second is the width (2 = 12 in., 5 = 15 in., 8 = 18 in.), the third is the depth (2 = 12, 5 = 15, 8 = 18, 1 = 21, 4 = 24 in.), and the fourth is the height (6 = 60 in. locker on a 66 in. frame, 8 = 72 in. on a 78 in. frame). The number after the dash is the tier count. So U1518-1 is a single 15 in. wide, 21 in. deep, 72 in. high one-tier locker.

What is the difference between a wardrobe locker and a box locker?

Tier count and latch. Wardrobe lockers are 1, 2 or 3 tier with openings from 24 to 72 in., and use a multi-point latch with a recessed handle. Box lockers are 4, 5, 6 or 16 tier with openings of 18 in. or 12 in., and use a projecting single-point friction catch pull. Wardrobe lockers take garments; box lockers take personal effects.

How tall is a locker really?

Taller than the locker height suggests. Standard lockers sit on 6 in. legs, so a 72 in. locker occupies 78 in. and a 60 in. locker occupies 66 in. Adding a sloped top adds its rise on top of that, which runs from about 4 in. on a 12 in. deep locker to about 8 in. on a 24 in. deep one. Always check the frame height, not the locker height.

Should I buy knock-down or assembled?

Compare installed cost, not purchase price. Knock-down suits large runs in accessible rooms where you have labor and freight cost matters. Assembled suits small quantities, awkward access, occupied buildings and jobs where assembly is billed at contractor rates. Note that some accessories, including coat rods and flat top fillers, are published for knock-down lockers only.

Do lockers come with locks?

Generally no, with the exception of the two factory-assembled Ready Built lines, both of which are published as including one combination padlock and a matching strike plate per door. On a six-tier Ready Built unit that is six padlocks, not one. Otherwise the lock is a separate line item: a built-in combination lock, a built-in key lock, or a padlock on a hasp. The built-in locks are published as not recommended for single-point-latch wardrobe doors, so confirm the latch type before ordering them.

How many accessible lockers does ADA require?

The 2010 ADA Standards section 225.2.1 requires that where lockers are provided, at least 5 percent, but no fewer than one of each type, comply with section 811. Section 308 sets the reach range at 48 in. maximum and 15 in. minimum above the floor. In practice that means accessible lockers are lower-tier openings. State and local codes can be stricter, so confirm with your architect or authority having jurisdiction.

What does OSHA require for employee lockers?

29 CFR 1910.141(e) requires that where employees must wear protective clothing because of possible contamination with toxic materials, change rooms be provided with storage for street clothes and separate storage for the protective clothing. That means two separate storage spaces per affected employee, which doubles the opening count for that headcount. General-purpose employee lockers outside that situation are not governed by this paragraph.

Which locker is right for wet or sweaty clothing?

The Heavy-Duty Ventilated line, which uses diamond-perforated doors and sides so air moves through the whole body rather than just past the door. It is published with 14 gauge doors on a 16 gauge frame and body. Standard louvered doors give only modest airflow, and damp clothing in a louvered locker is the usual source of locker room odor. Ventilation cannot be added later.

What should I use in a damp or corrosive environment?

Galvanite for dampness, corrosion-prone rooms, unheated buildings and coastal sites: it uses galvannealed steel throughout, a 24 gauge body and 16 gauge doors. Type 304 stainless for washdown, food, pharma and cleanroom, where chemicals or a hygiene standard require it. Stainless runs several times the price, so use Galvanite where the issue is only moisture.

When is an all-welded locker worth the money?

When the door being pried is a real risk, or the room sees genuine abuse. All-welded lockers are published at 12 gauge with 7 gauge welded legs and three-point locking with a padlock hasp, against 24 gauge on a standard knock-down body. They cost several times as much per opening and weigh hundreds of pounds. For tools, theft-prone areas and heavy industrial use they are the right answer; for a school or office they are not.

How do I quote a run of wire tenant lockers?

One starter and then add-ons, because each add-on shares framing with the unit before it. A ten-unit row is one -S and nine -A, not ten starters. The D variants (-DS and -DA) are double tier, meaning two compartments stacked in the same footprint, not a wider door.

Can I get a solid door instead of louvered?

The Hallowell wardrobe and box lines carried here publish louvered, polycarbonate or perforated doors rather than solid ones. If a fully solid door is required for privacy or containment, that points toward the all-welded industrial lockers, where solid doors are offered.

Section Fifteen

Quick-reference tables

Everything above, condensed.

Model number decoder

Hallowell: family + units wide + width + depth + height + tiers
PositionMeaningValues
LettersFamilyU Premium · URB Ready Built · USV Safety View · USVP Safety View box · UMS MedSafe · USS stainless · UCTL cell phone · BSL bulk storage · HERL emergency response · HLV Max View
Digit 1Units wide1 = single · 3 = three-wide
Digit 2Width2 = 12 in. · 5 = 15 in. · 8 = 18 in.
Digit 3Depth2 = 12 · 5 = 15 · 8 = 18 · 1 = 21 · 4 = 24 in.
Digit 4Height6 = 60 in. / 66 in. frame · 8 = 72 in. / 78 in. frame
After dashTiers1, 2, 3, 4, 5, 6, 16
SuffixVariantG Galvanite · HDV ventilated · A assembled · ASB assembled, slope top and closed base · WM wall mounted

Tier to opening height

Published opening heights by tier count
TiersOpeningHolds
160 or 72 in.Hanging garments, hat shelf above
236 in.Folded coat, bag, boots
324 in.Bags, boots, helmets
418 in.Safety View box line only
512 in.Wallets, phones, keys. Published on the 60 in. locker, 66 in. frame
612 in.Wallets, phones, keys. Published on the 72 in. locker, 78 in. frame

Construction by line

Published gauges and materials
LineBodyDoor
Premium wardrobe24 ga16 ga louvered
Premium box24 ga18 ga louvered
Safety ViewSteel16 ga with polycarbonate panel
Heavy-Duty Ventilated16 ga frame and body, perforated14 ga diamond perforated
Galvanite24 ga galvannealed16 ga galvannealed (18 ga box)
MedSafeAntimicrobial powder coat16 ga louvered
Max ViewAll-welded, 13 ga hinges, 16 ga shelves14 ga perforated
Strong Hold12 ga all-welded, 7 ga legsThree-point lock with hasp
WireCrafters tenant10 ga 2×2 in. mesh in 13 ga anglePadlockable

Accessory part numbers

Hallowell locker accessories by function
FunctionParts
Closed basesKCFB12/15/18 front · KCSB12/15/18/21/24 side · KCFB…SS, KCSB18SS stainless
Slope topsKISTT individual · SLST three-wide kit · CST1272/1572/1872 continuous, 72 in.
Slope end closuresKISE12/15/18/21/24 individual · CSE12/15/18/21/24 continuous
Flat top fillersKFTF 6 and 12 in. widths · FTC12/15/18/21/24 corners. Knock-down lockers only
Front fillersKFSF0666, KFSF1266 for 66 in. frames · KFSF0678, KFSF1278 for 78 in.
Slip jointsKG66 · KG78
Coat rodsKCR12, KCR15, KCR18, KCR24. Knock-down lockers only
Locks1970 built-in combination · 1770 built-in key · 1925 combination padlock
BenchesPedestals 4805, 4810, 4820, 4825, 4032 · maple tops MBT36 to MBT144

Compliance quick reference

Requirements that change what you order
RequirementFigureSource
Separate storage for street and protective clothingRequired where protective clothing may be contaminated with toxic materialsOSHA 29 CFR 1910.141(e)
Accessible lockersAt least 5%, no fewer than one of each typeADA 225.2.1
High reach48 in. maximumADA 308.2.1 / 308.3.1
Low reach15 in. minimumADA 308.2.1 / 308.3.1

Specify-it checklist

1. What goes inside, and who might break in?
Picks the family: knock-down steel, all-welded, or wire.
2. How many openings does the shift need?
Sets the tier count against the wall length you have.
3. Do people hang garments?
If yes, single tier. Nothing else takes a full-length coat.
4. Clear height available?
Locker height plus 6 in. legs, plus the slope top rise if fitted.
5. Wet, damp or corrosive?
Ventilated for moisture in clothing, Galvanite for corrosion, stainless for washdown.
6. Assigned or shift use?
Built-in combination for assigned, padlock hasp for shift. Check latch compatibility.
7. Who assembles it?
Knock-down, assembled option, or Ready Built. Decide before listing accessories.
8. Wall length minus locker run?
Order fillers and slip joints for the remainder on the same PO.
9. Protective clothing contamination risk?
Separate storage required. Double the openings for that headcount.
10. Accessible count and reach?
5% of each type, openings between 15 and 48 in. Confirm with your AHJ.