HomeBuyer's GuidesWireCrafters Style 840

CustomMHS Buyer's Guide

WireCrafters Style 840

One partition system, two very different meshes. Woven wire is interlocked at every crossing and blocks a hand. Welded wire is lighter and easier to cut openings in. Choosing between them is the first decision, and most of the rest of the specification follows from it.

Covers: Style 840 woven wire · RapidWire welded wire Questions: 866-333-0728
Section One

One system, two meshes

Getting the vocabulary straight, because the names are used loosely everywhere.

Style 840 is the partition system: the posts, the panel frames, the doors, the hardware and the way it all bolts together. What varies inside that system is the mesh, and there are two.

Heavy duty

Style 840 woven wire

10 gauge wire in a 2 in. by 1 in. rectangular opening, 2-1/8 by 1-1/8 in. centre to centre, interlocked at every crossing rather than fused.

Frame is 1-1/4 by 1-1/4 by 1/8 in. hot-rolled angle. Panels longer than 3 ft 6 in. carry flat steel stiffeners welded behind the mesh.

Medium duty

RapidWire welded wire

10 gauge wire in a 2 in. by 2 in. square mesh, welded at each intersection.

Positioned by the manufacturer as the line with quick ship time and fast installation features, and described as substitutable for the woven mesh where the application allows.

The naming trap

You will see "RapidWire" used loosely as an umbrella brand, including by resellers listing RapidWire woven panels. When you are quoting, do not rely on the line name. Confirm the mesh you are getting by its actual specification: 2 in. by 1 in. is the woven heavy-duty mesh, 2 in. by 2 in. is the welded medium-duty mesh. Those two numbers are unambiguous where the brand names are not.

What this guide covers, and what sits elsewhere

This is the product-line guide: how to read the part numbers and specify a system. For the broader category question, including how wire partitions compare with other security approaches and the reach-distance standards that govern guarding generally, see the Wire Partitions & Security Cages guide. For perimeter guarding around machinery, see also the Barriers & Machine Guarding guide, and note the warning in Section Thirteen about which product actually belongs around a machine.

Section Two

Woven or welded: the real comparison

Including two published figures that contradict the usual sales story.

The received wisdom is that welded wire is the cheaper, faster option and woven is the premium one. Two of those three claims do not survive contact with the published catalog.

What genuinely differs

Published differences between the two meshes
FactorWoven 2 in. by 1 in.Welded 2 in. by 2 in.
Tamper resistanceInterlocked at every crossing. Cutting one strand does not open a hole, because the surrounding weave holds the patternFused at each intersection. Cutting frees the cut wires
Reach throughThe 1 in. dimension blocks a hand and forearmThe 2 in. by 2 in. opening permits hand access
Weight, 8 ft by 4 ft panel53 lb38 lb
Weight, 8 ft by 5 ft panel63 lb44 lb
Cutting openingsNot published as a strengthCut outs can be made and the mesh never loses its shape
Duty ratingHeavy dutyMedium duty
Typical applicationTheft prevention, controlled substances, high-value inventorySeparation and traffic control rather than theft prevention

The weight difference is real and it is the largest measurable gap between the two: welded panels run roughly a quarter to a third lighter at the same size. On a big installation that is genuinely less material to lift into place.

Two claims the catalog does not support

Welded is not reliably cheaper. Compare the identically sized one-wall cages: the woven W581H and the welded RW581H are published within about one percent of each other. On at least one other published pair at the same size, the welded cage is the dearer of the two. The price relationship is not consistent, so check the actual quote for your configuration rather than assuming a saving.

There is no published lead-time advantage. RapidWire is positioned as quick ship, but that is never quantified in days, and the published fulfilment window is identical for the woven and welded versions of the same cage. If lead time is driving your decision, get it in writing for your specific configuration.

How to actually choose

Someone might cut in
Woven. The interlocked weave is the whole argument, and it is the only one of these factors that cannot be bought back later.
Someone might reach through
Woven. A 2 in. by 2 in. opening admits a hand; the 1 in. dimension does not.
Controlled substances
Woven. See Section Twelve. The published DEA specification uses the 2 in. by 1 in. mesh.
Keeping traffic out of an area
Welded is sufficient. Nobody is attacking a lunchroom partition.
You will cut openings for conveyor or ductwork
Welded. It is published as holding its shape through cut outs.
Large run, install labour is the constraint
Welded, for the weight saving. Confirm the price gap on your actual quantity first.
Visibility matters to a supervisor
Either. Both are open mesh, and the difference in sightline is small.
The honest summary

Choose woven when the partition is a security barrier and someone has a motive to get through it. Choose welded when the partition is a boundary and the job is to stop people wandering in. Do not choose welded expecting a large saving or a shorter lead time, because neither is published.

Section Three

Reading a model number

Not documented by the manufacturer. This is our reading of it, checked against published dimensions.

WireCrafters does not publish a key to its cage model numbers, but the pattern is consistent across the catalog and it is worth learning, because it tells you the mesh, the footprint and the door type at a glance.

W 66 8 4 H
W
Mesh: W is woven Style 840, RW is RapidWire welded
66
Footprint: 6 ft 6 in. by 6 ft 4 in.
8
Height class: the 8 ft 5-1/4 in. system
4
Number of walls
H
Door: H is hinged, S is sliding
Checked against published dimensions: W581H is a woven one-wall cage 5 ft 6 in. wide by 8 ft 5-1/4 in. high with a hinged door. RW581H is the same cage in welded mesh. RW161484H is a welded four-wall cage on a 16 by 14 ft footprint.
Treat this as a reading aid, not a specification

Because the scheme is not published, use it to compare quotes and to sanity-check that two part numbers describe the same thing. Always confirm the actual dimensions on the listing before ordering. Component part numbers use entirely different schemes, covered in the sections below.

The other numbering schemes

Component part numbers by family
ComponentSchemeExample
Woven panelsWidth in feet, then height in feet84 is 8 ft by 4 ft
Welded rack backing panelsBACK then width and heightBACK84 is 8 ft by 4 ft
PostsRP run or CP corner, then system height in feetRP8, CP12
Hinged doorsHD, width, opening height, system heightHD-47-10
Double hinged doorsDHD, same patternDHD-67-8
Sliding doorsSD, same patternSD-58-8
Rack enclosuresRE then width, height, depthRE9836
Driver cagesMT, wall count, width and depth digits, HDMT2-56HD
Tenant lockersWCTL, dimensions, then S starter or A adderWCTL333-S
Door numbers appear two ways

The same hinged door is published as HD-37-8 in the product catalog and HD378 in the CAD file library, with and without hyphens. They are the same part. If a drawing and a quote seem to disagree, check whether that is all it is.

Section Four

Panels and sizes

Stock sizes, weights, and the filler panel that saves the install.

Panels install horizontally between posts, with the mesh opening parallel to the floor. Stock widths run from 1 ft to 10 ft in one-foot increments, in two heights, 4 ft and 5 ft, which stack to make up the system height. The maximum panel is 12 ft wide by 5 ft high.

Published panel weights, woven against welded
Panel sizeWoven partWoven weightWelded partWelded weight
1 ft by 4 ft1413 lbBACK148 lb
2 ft by 4 ft2418 lbBACK2412 lb
4 ft by 4 ft4431 lbBACK4422 lb
6 ft by 4 ft6441 lbBACK6430 lb
8 ft by 4 ft8453 lbBACK8438 lb
10 ft by 4 ft10463 lbBACK10445 lb
8 ft by 5 ft8563 lbBACK8544 lb
10 ft by 5 ft10574 lbBACK10554 lb
12 ft by 4 ftNot stockedn/aBACK12458 lb
12 ft by 5 ftNot stockedn/aBACK12568 lb

The adjustable filler panel

Real buildings are not multiples of one foot. The adjustable filler panel closes the leftover gap at the end of a run: AP4 at 1 ft 2-3/8 in. by 4 ft, and AP5 at the same width by 5 ft. They are solid sheet metal and adjust from 1 in. to 11 in.

Order the filler with the run

Measure the wall, lay out the panel widths, and see what is left over. That remainder is the filler panel. It is the part most often discovered on install day, and a partition that stops 7 in. short of a wall is not a secure partition. One filler per open end.

Finish and colour

The finish is a grey enamel and the product is published as finished for interior applications. Note that the two published documents describe it differently, one as a prime coat of alkyd enamel applied electrostatically and the other as a coat of acrylic enamel, so confirm the finish specification on the quote if it matters to you. In-stock colours beyond the standard grey are white, blue, safety yellow, orange, tan, red and black. Custom powder coat matching is available at additional cost.

Interior only

The published finish is for interior applications. If the partition is going into a yard, an unheated open structure or anywhere weather reaches it, raise that at quote stage rather than assuming the standard finish will cope.

Section Five

Posts, base plates and anchoring

The part that makes the difference between a partition and a barrier.

Published post and anchoring specification
ItemPublished
Post section2 in. by 2 in. by 14 gauge square tubing, cold rolled structural grade
Base plate1/4 in. by 2 in. by 7 in. plate welded at the base of the post
Footplate projectionExtends about 2-1/2 in. outside the post at each post position
Maximum post spacing10 ft 2 in. centres
Floor anchors3/8 in. wedge anchors
Assembly hardware3/8 in. grade two plated, standard thread
Floor sweep3-1/4 in. on stock doors without a lower angle cover bar, 1-3/4 in. with one
Stock post heights8 ft 5-1/4 in. · 10 ft 5-1/4 in. · 12 ft 5-1/4 in. Special lengths available; published figures vary, confirm on the quote
Part numbersRP5 RP8 RP10 RP12 run posts · CP5 CP8 CP10 CP12 corner posts · CP12O offset corner

Hardware that faces the right way

The 3/8 in. hardware is specified as inaccessible from the exterior of the enclosure, against the 1/4 in. accessible hardware found on lighter systems. That is a security feature and it has a practical consequence: the enclosure has an inside and an outside, and it has to be assembled with the fasteners facing in. Getting that backwards on install turns a security cage into a bolt-together kit that anyone with a nut driver can dismantle.

The base plate is why post spacing matters

Panels bolt to posts, posts carry the load into the floor through the base plate, and the plate is anchored with 3/8 in. wedge anchors. Post spacing at more than 10 ft 2 in. is outside the published maximum. On DEA work the requirement is tighter still, at no more than 10 ft, with horizontal reinforcement. See Section Twelve.

Panels attach to posts with the nuts and bolts supplied, or with tek screws. The whole system is bolted; nothing is welded on site.

Section Six

Heights, ceilings and the top gap

Whether to run to the deck is a security decision with a real cost attached.

Standard system heights

Three stock system heights are published, set by the post: 8 ft 5-1/4 in., 10 ft 5-1/4 in. and 12 ft 5-1/4 in. These are the three that appear as options on cage listings. A shorter 5 ft 3-1/4 in. system height exists in the CAD library with its own posts but is not published as a stock height, so treat it as a made-to-order option. Custom heights extend to 50 ft for roof deck applications. Panels stack to make up the height, which is why the standard heights land on those odd fractions.

Height is a significant cost step, not a rounding. On a published four-wall woven cage, moving from the 8 ft to the 10 ft system adds several hundred dollars and moving to the 12 ft system adds several times that. Decide the height from the threat, not from the ceiling.

The climb-over problem

A partition that stops at 8 ft in a building with 24 ft clear height leaves 16 ft of open air above it. Anyone willing to climb a rack or a ladder is inside. The published position is direct: full-height panels that reach the ceiling or roof deck prevent anyone from climbing over the top.

Casual deterrence, staffed area
8 ft 5-1/4 in. is normally enough. There is nothing to climb from and someone would be seen.
Racking or mezzanine adjacent
Go taller, or add a ceiling. A rack next to a partition is a ladder.
High-value or controlled stock
Ceiling panels, or run to the structural deck. Half measures here are not security.
Unstaffed overnight
Ceiling or full height. Nobody is watching.

Ceilings

Ceiling panels are an option, not standard, and they are interchangeable with wall panels, attached with slotted angle. Ceiling systems clear span up to 30 ft. Cutouts and drop-down doors are available.

Ceiling panels are not load bearing

Published explicitly, and it is the point people get wrong. A wire ceiling closes the top of a cage against a person climbing in. It is not a platform, not a place to store anything, and nothing should be hung from it. If someone needs to walk above the cage, that is a mezzanine and a structural question, not a partition accessory.

Why the partition does not seal to the deck

Open mesh is not an accident of construction. The published rationale is that open wire supports airflow and fire suppression coverage, and lets existing lighting, ventilation and fire suppression systems keep working. A solid-walled room in the same position would need its own sprinkler design, lighting and ventilation. That is a genuine advantage of wire over drywall for interior enclosures.

Confirm sprinkler coverage with your own authority

There is no published clearance dimension for the gap between the top of a partition and the deck, and no fire code citation in the product literature. Sprinkler coverage over and inside an enclosure is a design question for your fire protection engineer and your authority having jurisdiction, particularly on ceiling panels and full-height enclosures. Do not treat the open mesh as automatically satisfying anything.

Section Seven

Doors

Three published families, and the one that fits depends on the floor space you do not have.

Door type is usually decided by clearance rather than preference. A hinged door needs swing space; a sliding door needs a clear wall run beside the opening to park itself against.

Hinged doors

Published at 3 ft or 4 ft wide with a 7 ft 3-1/4 in. high opening, on two door posts with three 4 by 4 in. hinges. Universal, so left or right hand and in or out swing are set at install rather than at order.

Single hinged doors
PartOpeningOverall heightWeight
HD-37-83 ft by 7 ft 3-1/4 in.8 ft 5-1/4 in.106 lb
HD-47-84 ft by 7 ft 3-1/4 in.8 ft 5-1/4 in.118 lb
HD-37-103 ft by 7 ft 3-1/4 in.10 ft 5-1/4 in.123 lb
HD-47-104 ft by 7 ft 3-1/4 in.10 ft 5-1/4 in.139 lb
HD-37-123 ft by 7 ft 3-1/4 in.12 ft 5-1/4 in.138 lb
HD-47-124 ft by 7 ft 3-1/4 in.12 ft 5-1/4 in.157 lb

Double hinged doors give a 6 ft or 8 ft opening at the same height, with the inactive leaf secured by a cane bolt and chain bolt: DHD-67-8 at 170 lb through DHD-87-12 at 251 lb. Specify a double where a pallet has to pass through and a sliding door will not fit.

Sliding doors

Published from 3 ft to 10 ft wide, supplied with two trolley trucks, track and hardware. Published opening heights are 8 ft 0-1/4 in. and 10 ft 0-1/4 in. These do not simply track the system height, so read the opening height from the part number rather than assuming it follows the post.

Sliding doors, 8 ft system, selected sizes
PartOpening widthWeight
SD-38-83 ft124 lb
SD-48-84 ft137 lb
SD-58-85 ft149 lb
SD-68-86 ft196 lb
SD-88-88 ft230 lb
SD-108-810 ft279 lb
A sliding door needs a parking wall

A sliding door does not swing, which is why it suits a busy aisle. But it has to slide somewhere, so it needs a clear run of partition beside the opening at least as wide as the door itself, with nothing stacked against it. Check that on the layout before choosing sliding over hinged.

Specials

Self-closing doors are an option, not a catalogued model

Self-closing and self-locking operation appears in the DEA requirements and a door closer is offered as a configurable option, but no self-closing door is published as a part number with a size. If your application requires it, specify it in writing on the order rather than assuming a model exists.

Section Eight

Locks, latches and exit devices

A wide published range, and a cost spread of more than ten to one.

The lock is a separate line item from the door, and the choice spans from a simple key lock to a card reader. The published range, with the front and back designations indicating the outside and inside of the door:

Published locking options
PartDescriptionFits
SF-1 / SB-1Key lock outside, recessed thumb turn knob insideHinged
SDLKXKDThe same key lock and thumb turn for a sliding doorSliding
SF2-SB1Thumb turn latch. Latches only, does not lockHinged or sliding
SF3-SB3Door knob entry with knob for easy exit. Latches only, does not lockHinged
SF1-SB4Key lock with lever handle back. Meets ADA requirementsHinged
CF1-CB1ADA handle setHinged
CE-2Ten digit keypad for an electric strike or magnetic lock, programmable for 64 codesEither
10DIGIT-eForceKeyless entry, ten digit keypad with lever handle, front onlyHinged
CF-2Five button coded access lockHinged
CE-3Magnetic lock for sliding doorsSliding
Card readerActivates an electric strike or magnetic lock, ships with ten cardsEither

Exit devices

Three are published: CB-2 a hand-sized push paddle, CB-3 a push bar running the full width of the door, and CD-4 an alarm push bar that sounds a battery-powered alarm when opened.

Egress is not optional

If anyone works inside the enclosure, they have to be able to get out without a key. Two of the published latch sets latch but do not lock, which is exactly right for a partition someone works behind. Where the door must lock, pair it with an exit device on the inside. This is a life safety requirement in your building code, not a WireCrafters option, so confirm it with your authority having jurisdiction rather than treating it as a preference.

Two ADA options are published

SF1-SB4 and CF1-CB1 are both published as meeting ADA requirements, and they are separated by a large price gap. If the enclosure is in a space subject to accessibility requirements, specify one of them and confirm the requirement with your architect.

The cost spread here is wide, from under two hundred dollars for a key lock to well over two thousand for a card reader or an alarm bar. On a multi-cage project the locking hardware can rival the cost of the partition, so price it early rather than as an afterthought.

Section Nine

One, two, three and four wall cages

Buy only the walls you do not already have.

Cages are sold by how many sides they supply, and the cheapest correct answer is the one that uses your building. Published configurations:

1 wall
Fits between two existing wallsA single run closing an alcove or a recess. The least material and the most common misjudgement, because it depends on both flanking walls being solid and full height.
2 wall
Corner installation or free standingUses two existing walls meeting at a corner, or forms an L in open floor.
3 wall
Against an existing wall, or free standingThe workhorse. One building wall does the back, the cage does the rest.
4 wall
Fully enclosed, with or without a ceilingFree standing in open floor, owing nothing to the building. Specify the ceiling separately.
Check what the existing wall actually is

A one-wall or three-wall cage assumes the building walls are as secure as the partition. A stud-and-drywall wall is not, and neither is a demising wall that stops at a suspended ceiling with open plenum above it. If the existing wall can be cut through or climbed over, you have bought a cage with a hole in it. Walk the perimeter before deciding how many walls to buy.

Named applications

Beyond the generic cages, the published application list includes tool cribs, server and colocation cages, evidence enclosures, tenant storage lockers and DEA controlled substance storage. Server and colocation cages are published as an application without model numbers or standard sizes, so those are quoted from a layout rather than picked from a table.

Tenant storage lockers are a related but distinct product line, the WCTL series, in welded mesh at 7 ft 6 in. high, quoted as starters and adders. They are covered in the Lockers guide.

Section Ten

Pallet rack enclosures and backing

Two different products that both bolt to racking, solving two different problems.

Rack backing, for the aisle behind

Rack backing panels stop product being pushed off the back of a rack into the next aisle. This is a falling-object problem, not a security one. Panels are the welded BACK series, in widths to 12 ft and heights of 4 ft and 5 ft, attached with mounting clips for teardrop uprights in flush, 1 to 3 in. offset, or 4 to 6 in. offset versions.

Get the offset right

The offset clip exists because pallets overhang the beam. If the backing sits flush against the upright and your pallets overhang by 3 in., the load presses on the mesh. Measure the actual overhang of a loaded pallet and pick the clip that clears it. Published offsets go up to 6 in., so an overhang beyond that needs to be raised at quote stage rather than assumed.

Rack enclosures, for the goods inside

Rack enclosures turn a rack bay into a locked cage. The RE series is published in 27 configurations, using 10 gauge wire welded into a 2 in. by 2 in. mesh in 13 gauge frames. Beam widths of 96, 108 and 120 in., heights from 8 to 12 ft, depths of 3 to 4 ft, and upright depth options of 36, 42 and 48 in. Mounting is by flush-mount angle clips or self-tapping screws. Three mounting clips are stocked, offering offsets from flush up to 6 in. to clear overhanging pallet loads; separate 12 in. long clips allow panels to be mounted between back-to-back rows of racking.

Rack double hinged doors are published separately: RDH888 at 8 ft wide by 8 ft high, and RDH810 at 8 ft by 10 ft.

Note the mesh

Rack enclosures are published in the welded 2 in. by 2 in. mesh. If the goods in that bay warrant the woven mesh, say so at quote stage rather than assuming the standard enclosure gives you the heavy-duty specification.

Freight on both products is palletised and charged by weight, so consolidate a rack project into one order rather than trickling panels in.

Section Eleven

Driver and dock door cages

The MT series, and the one application with a published size table.

A driver cage puts an incoming truck driver in a defined, visible space with a counter to do paperwork, instead of loose on the dock floor. It is the cheapest single control most distribution operations can apply to dock-side shrink, and the MT series is published as a straightforward size table.

Published MT series driver cage sizes
WidthTwo wall modelsThree wall modelsDoor
3 ft 4 in.MT2-33HD MT2-34HD MT2-36HD MT2-38HDMT3-33HD MT3-34HD MT3-36HD MT3-38HD3 ft hinged
4 ft 4 in.MT2-44HD MT2-46HDMT3-44HD MT3-46HD MT3-48HD4 ft hinged
5 ft 6 in.MT2-54HD MT2-56HD MT2-58HDMT3-54HD MT3-56HD MT3-58HD4 ft hinged
6 ft 6 in.MT2-64HD MT2-66HD MT2-68HDMT3-64HD MT3-66HD MT3-68HD4 ft hinged
7 ft 6 in.MT2-74HD MT2-76HD MT2-78HDMT3-74HD MT3-76HD MT3-78HD4 ft hinged
8 ft 6 in.MT2-86HD MT2-88HDMT3-86HD MT3-88HD4 ft hinged

Depths run 3 ft 4 in., 4 ft 4 in., 6 ft 4 in. and 8 ft 4 in. as indicated by the second digit. Two-wall models sit in a corner and use two building walls; three-wall models need only one. Benches are published separately as MTB-4, MTB-6 and MTB-8 at 4, 6 and 8 ft long.

Specify the service window

Published options include a service window with a shelf, giving the driver a counter to sign and collect paperwork without entering the warehouse, and a pedestrian hinged door for staff access. The window is what makes the cage work as a process rather than as a holding pen, because the driver never needs to come inside. Service windows and Dutch doors are published separately, so say which you want rather than describing the function and hoping.

Section Twelve

DEA controlled substance storage

The one application where the specification is written into federal regulation.

Cages for controlled substances are not a matter of preference. 21 CFR 1301.72(b)(4) sets out what a cage has to be, and the specification is prescriptive enough to check line by line.

21 CFR 1301.72(b)(4), the cage specification
CitationRequirement
(b)(4)(i)Walls of not less than No. 10 gauge steel fabric mounted on steel posts
(b)(4)(i)(a)Posts at least one inch in diameter
(b)(4)(i)(b)Posts set in concrete, or installed with lag bolts that are pinned or brazed
(b)(4)(i)(c)Posts placed no more than ten feet apart, with horizontal one and one-half inch reinforcements every sixty inches
(b)(4)(ii)Mesh openings of not more than two and one-half inches across the square
(b)(4)(iii)A ceiling of the same material, or a cage that reaches and is securely attached to the structural ceiling of the building. A lighter gauge mesh may be used for the ceilings of large enclosed areas if walls are at least 14 feet in height
(b)(4)(iv)A door constructed of No. 10 gauge steel fabric on a metal door frame in a metal door flange, conforming in all other respects to 1301.72(b)(3)(ii)
(b)(4)(v)An alarm system that on unauthorized entry transmits a signal directly to a central station protection agency or a local or state police agency having a legal duty to respond, or to a 24-hour control station operated by the registrant, or to such other source of protection as the Administrator may approve

How the published specification maps to it

WireCrafters publishes a DEA configuration that reads directly against those paragraphs: 10 gauge wall and ceiling panels in the 2 in. by 1 in. woven mesh, 2 in. square steel posts set no more than 10 ft apart with base plates for anchoring, horizontal reinforcement of minimum 1-1/2 in. bars every 5 ft, self-closing and self-locking doors, and 3/8 in. hardware not accessible from the exterior. Panels mount flush to the floor and stack to height, with clear-spanning ceilings.

Note two things about the mesh. The regulation's limit is openings of not more than 2-1/2 in. across the square, which both the woven 2 by 1 and the welded 2 by 2 satisfy on that dimension alone. What is published for DEA work is nonetheless the woven mesh, and that is the right instinct: the regulation sets a floor, and controlled substance storage is not the place to specify to the minimum.

No cage is DEA approved, and nobody can sell you one that is

"DEA approved" appears in marketing across this industry, including in some page names. The DEA does not approve, certify or list cages. What the regulation does is describe construction requirements, and a registrant is responsible for meeting them at their own site. A cage built to the specification above is compliant construction; whether your storage is compliant depends on the installation, the alarm, and the operational controls around it.

The alarm is part of the regulation

Paragraph (b)(4)(v) requires an alarm system. Note that it permits more than one route: a signal to a central station protection agency or a local or state police agency having a legal duty to respond, or to a 24-hour control station operated by the registrant, or to another source of protection the Administrator approves. A registrant already running a 24-hour control station may not need third-party monitoring. Either way it is not a WireCrafters line item, and it is the requirement most often missed when someone budgets for a cage alone. Similarly, paragraph (b)(4)(i)(b) requires posts set in concrete or lag bolts that are pinned or brazed, which is an installation requirement rather than a product one. A correctly built cage badly anchored does not comply.

Schedules and scope

Requirements tier by schedule, with Schedule I and II typically requiring the highest level of security and Schedules III through V permitted in approved secure areas such as cages, rooms or cabinets meeting the applicable standards. Confirm which schedules you handle, and which paragraph of 1301.72 applies to your registration, with your compliance officer before specifying. The published product pages scope themselves to Schedule III through V.

Operational controls sit alongside the physical ones: access logging, inventory accountability, receiving controls, cycle counts, discrepancy workflows and DEA Form 106 reporting for losses. The cage is one control among several.

Section Thirteen

Machine guarding is a different product

Do not specify Style 840 around a machine without reading this.

WireCrafters makes a dedicated machine guarding system, RapidGuard II, and it is not Style 840 with a different label. The specifications differ in the ways that matter for guarding.

RapidGuard II against Style 840
SpecificationRapidGuard IIStyle 840 woven
Mesh10 gauge welded, 1-1/4 in. square centre to centre10 gauge woven, 2 in. by 1 in.
Frame1-1/4 in. by 1-1/4 in. 13 gauge roll formed angle1-1/4 in. by 1-1/4 in. by 1/8 in. hot rolled angle
Panel heights6 ft 1-1/2 in. and 8 ft4 ft and 5 ft, stacked
Panel widths1 ft to 5 ft1 ft to 10 ft
Base plate6 in. square by 1/4 in.1/4 in. by 2 in. by 7 in.
Hardware5/16 in. tool removable3/8 in. standard
Sweep4 in.3-1/4 in.

Two features are specific to guarding. The lift-off design lets a panel be removed while the fixing hardware stays attached to the post, which is published against RIA TR R15.406. The tool removable hardware means a guard cannot be opened without a tool, which is published against ANSI B11.19. The 1-1/4 in. mesh opening is also markedly smaller than either partition mesh.

Mesh opening and safety distance are an engineering calculation

How far a guard must stand off from a hazard is a function of the barrier height, the mesh opening and the reach each permits, and it is governed by safety distance standards. The WireCrafters product literature does not publish a reach-through or safety distance table, so the standoff cannot be read off a product page. Our Barriers & Machine Guarding guide does publish illustrative fence height and distance values drawn from ISO 13857, alongside ISO 13855, ANSI B11.19 and ANSI/RIA R15.06, and that is the place to start. Even so, those values are illustrative. The standoff that applies to your equipment comes from a risk assessment performed on it, not from any table, including ours.

Style 840 has legitimate uses around equipment, particularly for perimeter access control on large cells where the barrier is about keeping people out of an area rather than guarding a specific point of operation. But the moment the question becomes how close a guard can sit to a hazard, you are in machine guarding, and that is RapidGuard territory and a risk assessment.

Section Fourteen

Installation

Bolted, not welded, and not a one-person job.

The system is entirely bolted. Panels attach to posts with the supplied nuts and bolts or with tek screws, posts anchor to the slab with 3/8 in. wedge anchors, and no welding appears anywhere in the published installation method. Panels and posts ship tagged with numbers for assembly.

Crew size is published

The installation manual states that installation is best accomplished with a two or three person crew. Panels run from 13 lb up to 74 lb and doors from 106 lb to nearly 390 lb, held at height while being bolted. Budget for a crew, not for one person and a weekend.

Published tool list

Worth passing to whoever is installing, because most of it is not in a general toolbox:

No published install time

There is no published estimate in hours, man-hours or linear feet per day for either mesh. If an installer quotes you a duration, that is their estimate rather than a manufacturer figure. The 48 hour figure that appears in the literature refers to shipping stock items, not to installation.

Two things to get right on the day

Section Fifteen

Common and costly mistakes

Twelve things that go wrong on wire partition orders.

  1. Choosing welded to save money without checking. On some published one-wall cages the woven and welded versions are within about one percent of each other, while on others the welded version is the dearer of the two. The saving people assume is there is not reliably there.
  2. Choosing welded for a shorter lead time. No lead-time advantage is published, and the fulfilment window is the same for both meshes on the same cage. Get it in writing for your configuration.
  3. Specifying welded where reach-through matters. A 2 in. by 2 in. opening admits a hand. If someone can reach the goods, the partition is decoration.
  4. Buying a one-wall or three-wall cage against a wall that is not secure. Drywall, or a demising wall that stops at a suspended ceiling, is not a cage wall. Walk the perimeter first.
  5. Stopping at 8 ft next to racking. A rack beside a partition is a ladder. Either go taller or add a ceiling.
  6. Treating a ceiling panel as a floor. Ceiling panels are published as non load bearing. Nothing goes on them and nothing hangs from them.
  7. Forgetting the filler panel. Buildings are not multiples of one foot. Measure the run, and order the adjustable filler for the remainder on the same order.
  8. Assembling with the hardware facing out. The 3/8 in. hardware is meant to be inaccessible from outside. Backwards, the cage unbolts from the wrong side.
  9. Specifying a sliding door with nowhere to slide. It needs a clear run of partition beside the opening, at least the width of the door, kept clear.
  10. Locking a door someone works behind, with no exit device. Egress is a code requirement. Pair a locking door with a push paddle or bar inside.
  11. Budgeting a DEA cage without the alarm. An alarm system is required by 1301.72(b)(4)(v), though the regulation permits a registrant-operated 24-hour control station as well as third-party monitoring. The anchoring method is in the regulation too.
  12. Using a partition mesh for machine guarding. Guarding is RapidGuard II and a risk assessment. Safety distance is not something to read off a catalog.
Section Sixteen

Frequently asked questions

The questions that come up most often on wire partition quotes.

What is the difference between Style 840 woven and RapidWire welded?

Both use 10 gauge wire. The woven mesh has a 2 inch by 1 inch opening and is interlocked at every crossing, so cutting one strand does not open a hole and the 1 inch dimension blocks a hand and forearm. The welded mesh has a 2 inch by 2 inch opening fused at each intersection, is roughly a quarter lighter, and holds its shape when cut outs are made. Woven is rated heavy duty and welded medium duty. Choose woven when someone has a motive to get through the barrier, welded when the job is keeping people out of an area.

Is welded wire cheaper than woven?

Not reliably. On some published pairs the two are within about one percent of each other, and on at least one published pair the welded cage is materially more expensive than the woven one at the same size. The consistent difference is weight rather than price: a welded 8 foot by 4 foot panel is 38 pounds against 53 pounds for the woven equivalent. If a saving is driving your decision, ask for both prices on your actual configuration rather than assuming.

How do I read a WireCrafters model number?

W means woven and RW means RapidWire welded. The digits that follow give the footprint, then the height class, then the number of walls, and the final letter is H for hinged or S for sliding. So W6684H is a woven four-wall cage on a 6 foot 6 inch by 6 foot 4 inch footprint in the 8 foot 5-1/4 inch height class with a hinged door. This scheme is not published by the manufacturer; it is our reading of the catalog, so confirm dimensions on the listing.

What heights are available?

Three stock system heights are published, set by the post: 8 feet 5-1/4 inches, 10 feet 5-1/4 inches and 12 feet 5-1/4 inches. A 5 foot 3-1/4 inch system exists with its own posts but is not published as a stock height. Custom heights extend to 50 feet for roof deck applications. Panels come in 4 foot and 5 foot heights and stack to make up the system height, which is why the standard heights land on those fractions.

Do I need a ceiling on the cage?

If anything can be climbed near the partition, or if the area is unstaffed, yes. A partition stopping at 8 feet in a building with 24 feet of clear height leaves the top open. Ceiling panels are interchangeable with wall panels and clear span up to 30 feet. They are not load bearing, so nothing can be stored on them or hung from them.

What makes a cage DEA compliant?

21 CFR 1301.72(b)(4) requires walls of not less than No. 10 gauge steel fabric on steel posts at least one inch in diameter, set in concrete or with lag bolts pinned or brazed, no more than ten feet apart, with horizontal one and one half inch reinforcements every sixty inches. Mesh openings must not exceed two and one half inches across the square. A ceiling of the same material is required, or the cage must reach and be securely attached to the structural ceiling, with a lighter gauge mesh permitted on ceilings of large enclosed areas where walls are at least 14 feet high. The door must be constructed of No. 10 gauge steel fabric on a metal door frame in a metal door flange. An alarm system is required, transmitting on unauthorized entry to a central station or police agency having a legal duty to respond, to a 24-hour control station operated by the registrant, or to another source the Administrator approves.

Can I buy a DEA approved cage?

No, and neither can anyone else. The DEA does not approve, certify or list cages, despite the phrase appearing widely in industry marketing. The regulation describes construction requirements and the registrant is responsible for meeting them at their site. A cage built to the specification is compliant construction; whether your storage complies also depends on the installation, the alarm and your operational controls.

Can I use Style 840 for machine guarding?

For perimeter access control around a large cell, where the job is keeping people out of an area, yes. For guarding a specific point of operation, no: WireCrafters makes a dedicated system, RapidGuard II, with a 1-1/4 inch square mesh, tool removable hardware published against ANSI B11.19 and a lift-off design published against RIA TR R15.406. The product literature publishes no reach-through or safety distance table, so the standoff cannot come from a product page. Our Barriers and Machine Guarding guide gives illustrative height and distance values from ISO 13857, but the distance that applies to your equipment must come from a risk assessment performed on it.

Hinged or sliding doors?

Hinged doors need swing space and come in 3 foot and 4 foot widths, or 6 foot and 8 foot as doubles. Sliding doors need no swing but need a clear run of partition beside the opening at least as wide as the door, kept clear of stock, and are published from 3 to 10 feet wide. In a busy aisle sliding usually wins; where a pallet must pass and there is floor space, a double hinged door is simpler.

How is it installed, and can one person do it?

It is entirely bolted, with no site welding. Panels bolt to posts with supplied hardware or tek screws, and posts anchor to the slab with 3/8 inch wedge anchors. The installation manual states the work is best accomplished with a two or three person crew, so no, not a one person job. Panels run to 74 pounds and doors to nearly 390 pounds, held at height while being fixed. No install time estimate is published.

What lock options are there?

A wide range, from a simple key lock with a thumb turn inside, through latch-only sets that do not lock, to keypads, a five button coded lock, magnetic locks for sliding doors and a card reader. Two options are published as meeting ADA requirements. Exit devices include a push paddle, a full width push bar and an alarmed push bar. Cost spans more than ten to one across that range, so price the hardware early on a multi-cage project.

Can it go outdoors?

The standard finish is a grey enamel and the product is described as finished for interior applications. If the partition is going somewhere weather reaches it, raise that at quote stage rather than assuming the standard finish will cope.

Section Seventeen

Quick-reference tables

Everything above, condensed.

Mesh at a glance

The two partition meshes and the guarding mesh
ProductMeshFrameDuty
Style 840 woven10 ga, 2 in. by 1 in. woven1-1/4 by 1-1/4 by 1/8 in. angleHeavy
RapidWire welded10 ga, 2 in. by 2 in. welded1-1/4 by 1-1/4 in. angleMedium
RapidGuard II10 ga, 1-1/4 in. square welded1-1/4 by 1-1/4 in. 13 ga roll formedMachine guarding

System specification

Published figures for the Style 840 system
ItemPublished
Panel widths1 ft to 10 ft stock, 12 ft maximum
Panel heights4 ft and 5 ft, stacked
Panel weights13 to 74 lb woven, 8 to 68 lb welded
Filler panelsAP4 and AP5, adjustable 1 in. to 11 in.
Posts2 by 2 in. 14 gauge square tube
Base plate1/4 by 2 by 7 in.
Max post spacing10 ft 2 in. centres
Floor sweep3-1/4 in., or 1-3/4 in. with a lower angle cover bar
Stock system heights8 ft 5-1/4, 10 ft 5-1/4, 12 ft 5-1/4 in.
Custom heightSystems published to 50 ft for roof deck applications
Ceiling clear spanUp to 30 ft, non load bearing
Hardware3/8 in., inaccessible from exterior
Anchors3/8 in. wedge anchors
FinishGrey enamel, interior use. Alkyd and acrylic both published; confirm on the quote
Stock coloursGrey, white, blue, safety yellow, orange, tan, red, black
Install crewTwo or three people

Regulatory reference

Standards named in this guide
RequirementFigureSource
DEA cage wall materialNot less than No. 10 gauge steel fabric21 CFR 1301.72(b)(4)(i)
DEA post diameterAt least 1 in.1301.72(b)(4)(i)(a)
DEA post anchoringSet in concrete, or lag bolts pinned or brazed1301.72(b)(4)(i)(b)
DEA post spacingNo more than 10 ft, 1-1/2 in. reinforcement every 60 in.1301.72(b)(4)(i)(c)
DEA mesh openingNot more than 2-1/2 in. across the square1301.72(b)(4)(ii)
DEA doorNo. 10 gauge steel fabric on a metal door frame in a metal door flange1301.72(b)(4)(iv)
DEA ceilingSame material, or attached to the structural ceiling. Lighter mesh allowed on large areas where walls are 14 ft or higher1301.72(b)(4)(iii)
DEA alarmCentral station or police with a duty to respond, a registrant-operated 24-hour control station, or an Administrator-approved alternative1301.72(b)(4)(v)
Guard hardwareTool removableANSI B11.19
Guard lift-off designPanel removable, fixing stays on postRIA TR R15.406

Specify-it checklist

1. Is anyone motivated to get through it?
Yes means woven. No means welded is sufficient.
2. Can they reach the goods through the mesh?
If reaching in gets them what they want, woven.
3. How many walls does the building already give you?
Buy the rest. Check the existing walls are actually secure and full height.
4. Can anything be climbed nearby?
Then go taller or add a ceiling. A rack is a ladder.
5. Wall length minus panel widths?
That remainder is your filler panel. Order it now.
6. What has to pass through the opening?
Pallet, person or paperwork. That picks hinged, double, sliding or Dutch.
7. Is there room for a door to swing or slide?
Sliding needs a clear parking run beside the opening.
8. Does anyone work inside it?
Then it needs an exit device or a latch that does not lock.
9. Controlled substances?
Woven, ceiling or deck attachment, compliant anchoring, and an alarm. Confirm with your compliance officer.
10. Anywhere near a machine hazard?
That is RapidGuard II and a risk assessment, not a partition.