Section OneDo you need wire decking?
It depends on what you store and how well your pallets span the beams.
Short answer: You need decking when anything stored could fall between the beams: cartons, undersized or damaged pallets, mixed pallet sizes, or hand-stacked product. Full-size pallets in good condition can sit on the beams alone.
Quick answers- Use decking for: Hand-stacked cartons, mixed pallet sizes, pallets smaller than the frame depth, and any level people pick from.
- Why wire and not solid: Open mesh lets sprinkler water reach the levels below. Solid decking blocks that path.
- Capacity: Ratings are for evenly spread static loads. A point load will not carry the rated figure.
A selective rack is a set of beams. A pallet that is the right size and in good shape bridges the front and rear beam by itself. Everything else needs something under it, and wire decking is the standard answer.
A note on this guideThis guide is written from published manufacturer data and my own experience quoting this equipment. It is general guidance and my opinion, not engineering advice. Confirm the rating for your exact model and application before you order.
Section TwoWire deck styles and how they fit the beam
The deck has to match the beam profile.
Short answer: Step beams take a waterfall deck that drops into the step. Box and structural beams need flared or inverted channels.
A wire deck is a welded mesh panel on steel support channels that run front to back. Worldwide Material Handling publishes a standard mesh of 2-1/2 x 4 in. in 6 gauge wire, 14 or 16 gauge support channels and a 1-1/2 in. waterfall at the front and rear. The waterfall is the mesh edge that turns down over the beam face and keeps the deck from sliding.
Deck styles| Style | How it sits | Typical use |
|---|
| Waterfall with step channels | Channels drop into the beam step, mesh folds over the beam face | Roll-formed step beams |
| Flared channel | Channel ends flare out to rest on top of the beam | Box beams and structural channel beams, mixed beam styles |
| Inside waterfall | Mesh turns down inside the beams, leaving the beam face clear | Where labels or scan tags go on the beam face |
| Inverted or flat deck | Channels face down so the top is smooth | Small items and cartons that slide |
Tell us the beam style and step depth before you order. The solid decking we list fits 1-5/8 in. step beams specifically, which shows how exact the fit is.
Section ThreeCapacity: reading the rating
The number on the listing has conditions attached.
Short answer: Deck capacity is for a uniformly distributed static load. More support channels and shallower depths carry more.
Husky wire deck capacity per panel| Panel depth | Three channels | Four channels |
|---|
| 36 in. | 3,250 lb | 3,900 lb |
| 42 in. | 2,610 lb | 3,150 lb |
| 48 in. | 2,100 lb | 2,630 lb |
Husky Quick Ship wire decking is made to comply with ANSI MH26.2, the standard for rack decking. That standard defines a uniformly distributed load as a static load spread evenly over the whole deck surface. A pallet covering the deck qualifies. A drum, a machine base or a coil sitting on a small footprint does not, and it will not carry the rated figure.
Two rulesNobody should stand on wire decking. And the deck rating never raises the beam rating: the level holds whatever is lower.
Section FourSizing and counting decks
Decks are named by depth and width.
Short answer: Deck depth matches the frame depth. Decks per level equals beam length divided by panel width, rounded down.
Husky deck numbers read depth, then width, then channels. A 4846A3 is 48 in. deep by 46 in. wide with three support channels. A 4852A3 is 48 x 52 in. Depths are 36, 42 and 48 in.
Decks per level| Beam length | Deck width | Decks per level |
|---|
| 96 in. | 46 in. | 2 |
| 108 in. | 52 in. | 2 |
| 144 in. | 46 in. | 3 |
Worked example
Ten bays, three levels, 108 in. beams and 42 in. deep frames. Each level takes two 52 in. wide decks, so 2 x 3 x 10 = 60 decks. Two three-channel 42 in. decks are rated 2,610 lb each, or 5,220 lb for the level. The published IBX43108 beam is rated 5,060 lb per pair. The beams are the limit, so the level is good for 5,060 lb.
Section FiveFire code basics: wire, perforated or solid
Decking is part of the fire protection picture.
Short answer: Open wire mesh lets ceiling sprinkler water pass down through the rack. Solid decking does not.
This is the main reason wire replaced plywood and solid steel as the default deck. Water from ceiling sprinklers has to reach a fire on a lower level. An open mesh deck lets it through. A solid deck sheds it into the aisle and shields the fire below.
Deck materials compared| Deck | Water passes through | Published detail | Use it when |
|---|
| Wire mesh | Yes | 2,100 to 3,900 lb per panel by size | Most pallet and carton storage |
| Perforated steel | Partly, depends on open area | See data sheet | Small parts that would fall through mesh |
| Solid steel | No | 14 gauge on 12 gauge channels, 3,000 lb per section | Dense small items, where the fire protection design allows it |
If you are adding solid decking, plywood or liners over existing wire, you are changing how the rack was designed to be protected. Treat it as a fire protection change, not a housekeeping change.
Section SixAlternatives and common mistakes
Decking is not the only way to support a load.
Short answer: Crossbars support an undersized pallet for less money, but they do not catch loose product.
Crossbars run front to back between the beams. They are listed at 36, 42 and 48 in., and the drop-in structural cross support bar is rated 5,000 lb. Two bars under a pallet keep it from dropping through. They do nothing for a carton.
- Point loading the deck. A deck rated 2,500 lb evenly loaded will not hold a 2,500 lb die on four feet.
- Ordering the wrong fit. Deck depth has to equal frame depth, and the channel has to match the beam step.
- Adding deck ratings above the beam rating. The lower of the deck total and the beam pair rating governs.
- Covering the mesh. Shrink wrap, cardboard or plywood laid over the mesh blocks the water path.
See pallet rack components for the full parts list and the pallet racking guide for layout.
Section SevenFrequently asked questions
The questions I hear most on quote calls.
Do I need wire decking on pallet racking?
You need it when stored items could fall between the beams, such as cartons, hand-stacked product, undersized pallets or mixed pallet sizes. Full-size pallets in good condition can sit directly on the beams.
How much weight can wire decking hold?
Husky wire decks are rated from 2,100 lb to 3,900 lb per panel depending on depth and the number of support channels. The rating is for an evenly distributed static load.
How many wire decks do I need per level?
Divide the beam length by the deck width and round down. A 96 in. beam takes two 46 in. decks and a 144 in. beam takes three.
What standard covers wire decking?
ANSI MH26.2 covers the design, testing and use of industrial storage rack decking.
Why is wire decking preferred over solid decking?
Open mesh lets sprinkler water reach lower rack levels, and it lets light and air through. Solid decking blocks that path.
Can I stand on wire decking?
No. Wire decking is rated for evenly distributed static loads, not for foot traffic.